PS-PUA-03 / Engineered System
PolyShield Metal Roof
Elastic protection for metal roofs and guttersCorrosion, laps and waterproofing treated as one integrated renovation challenge.

PS-PUA-03 / Engineered System
Corrosion, laps and waterproofing treated as one integrated renovation challenge.
What this system was developed for
Metal industrial halls
Gutters and valley gutters
Overlapping and fastenings
Large airless suitable roof areas
Steel
Galvanized metal
Existing compatible coating after test
Combination of corrosion control and waterproofing
Suitable for complex profiling
Airless potential on large surfaces
Reflective variant possible
For a metal commercial roof, a polyurea system must not only bridge leakage, but also address corrosion levels, existing coating, deformation, fastenings and condensation risk. Pretreatment and primer determine reliability.
Complete system construction
De getoonde opbouw is een eerste richting. Primer, laagdikte, verbruik en details worden pas definitief na inspectie, proefvlak en controle van de productgegevens.
Degrease, desalt and remove loose corrosion
Tune in to metal and exposure
Overlapping, screwing and sealing gutters
Weatherproof waterproof protection
Eerst technisch controleren
Corrosion degree and residual wall thickness
Salt and fat tax
Existing coating and adhesion
Condensation risk
Environmental control during spraying
Project registration
Pretreatment degree
Adhesion test
Primer and layer thickness registration
Spraying and environmental plan
Projectinformatie in opbouw
Tot die tijd tonen we geen generieke of geleende projectclaim. Deel uw projectsituatie voor een voor het betreffende project beoordeling.
Have a project assessed ↗Frequently asked technical questions
A membrane does not replace corrosion testing or metal repair. Loose corrosion, salts, weakened parts and existing coatings must first be treated appropriately.
This is possible in suitable large zones, provided product documentation, wind, overspray, air inlets, environment and shielding allow this.
Not automatically. Condensation is caused by building physical conditions and requires a separate analysis
Technical floor
AttachmentThe primer function depends on the substrate, porosity, moisture and the chosen membrane technology.
Lees technisch antwoord ↗
Application methodEquipment, response time, project environment and geometry determine which polyurea route is appropriate.
Lees technisch antwoord ↗
Layer thicknessOptical coverage is not proof of layer thickness; material quantity is linked to work area and surface.
Lees technisch antwoord ↗