POLYSHIELDSYSTEMSProject bespreken

NEW BUILD / ROOF SYSTEMS

Seamless 2K waterproofing around complex installations.

New construction and installation roofs increasingly contain penetrations, upstands, cable routes and technical installations. A liquid 2K membrane can follow complex geometry seamlessly, provided that roof structure, moisture, fire performance and details have been released in advance.
Discuss this building partView system matrix

Activities

New construction roofs and installation roofs as a complete system scope.

New construction and installation roofs increasingly contain penetrations, upstands, cable routes and technical installations. A liquid 2K membrane can follow complex geometry seamlessly, provided that roof structure, moisture, fire performance and details have been released in advance.

  • Installation roofs
  • Utility roofs
  • Roofs with many penetrations
  • Concrete roof structures
  • White and reflective roof concepts
PROBLEM → RISK → SOLUTION

The technique must be clear before implementation.

01 / PROBLEM

Many installations and interfaces increase the chance that small detail errors will later affect the entire roof function.

02 / PROJECT RISK
  • Inaccessible details after installation
  • Moisture trapped in the roof structure
  • Incorrect connection to non-standard materials
  • Non-demonstrable fire performance
  • Damage due to follow-up work
03 / POLYSHIELD ROUTE

PolyShield koppelt een koud aangebracht 2K-membraan aan detailplanning, hechtingscontrole, voor het betreffende project primer en een aantoonbare totale dakopbouw.

Project value

What the complete system delivers.

  1. 01Seamlessly around complex shapes
  2. 02No open flame during application
  3. 03Fast reacting membrane
  4. 04White UV-resistant version possible
  5. 05Documentation per roof zone
TECHNICAL ROUTE

Four manageable phases.

01

Test roof structure

Substrate, insulation, vapor barrier, moisture and fastening are considered as a total construction.

02

Primer and detail route

Materials and connections receive appropriate preparation and controlled detailed construction.

03

2K membrane

The liquid membrane forms a continuous, UV-resistant waterproofing layer.

04

Release

Adhesion, consumption, weather conditions and details are recorded before transfer.

Release criteria

When the system can — and cannot yet — start.

Moisture in the build-up

Wet insulation or trapped construction moisture must be examined first; a membrane should not mask this.

Fire performance

BROOF(t1) is only mentioned when the complete selected roof structure has been demonstrably tested for this purpose.

Installation planning

Plinths, penetrations and cable routes must be technically ready and accessible.

QUALITY FILE

Don't just apply.
Also deliver demonstrably.

  • Roof zone and detail plan
  • Adhesion and substrate control
  • Registration of weather and consumption
  • Evidence for the chosen structure
  • Delivery file with detailed photos
View our documentation method
FOR THE CONSTRUCTION TEAM

Information for every decision maker.

Main contractor

Fewer surprises between roofing and installation technology.

Installation partner

Clear connection conditions around pedestals, penetrations and cable routes.

Real estate investor

A maintainable roof with traceable system information.

Technical questions

Frequently asked questions.

Is every 2K membrane suitable as a final layer?+

No. UV resistance, surface, load and certification differ per technology and construction.

Can solar panels be installed later?+

Yes, when loading, fastening, walkways and protection are included in the design in advance.

Is a white roof automatically energy efficient?+

A light finish can limit surface temperature and heat load, but the actual building effect depends on insulation, climate installation and use.

Beoordeling in de praktijk

Wat moet bij nieuwbouwdaken en installatiedaken vóór uitvoering duidelijk zijn?

New construction and installation roofs increasingly contain penetrations, upstands, cable routes and technical installations. A liquid 2K membrane can follow complex geometry seamlessly, provided that roof structure, moisture, fire performance and details have been released in advance.

Wanneer dit meestal past

Moisture in the build-up

Wet insulation or trapped construction moisture must be examined first; a membrane should not mask this.

Fire performance

BROOF(t1) is only mentioned when the complete selected roof structure has been demonstrably tested for this purpose.

Installation planning

Plinths, penetrations and cable routes must be technically ready and accessible.

Wat we eerst willen weten

  • Roof zone and detail plan
  • Adhesion and substrate control
  • Registration of weather and consumption
  • Evidence for the chosen structure
  • Delivery file with detailed photos

Wanneer we een andere aanpak adviseren

Onbereikbare details na installatie Vocht opgesloten in de dakopbouw Onjuiste aansluiting op afwijkende materialen Niet-aantoonbare brandprestatie Schade door vervolgwerk

FROM ORIENTATION TO PROJECT DECISION

Connect to the phase your project is currently in.

You do not have to choose a system or product yet. Start with the information that is already available; we identify what is still technically lacking.