POLYSHIELDSYSTEMSProject bespreken

Our premium 2K system

Premium 2K polyurea waterproofing

Complete cold-applied two-component system for seamless waterproofing of technically suitable commercial roofs and structures. From surface control and primer to reinforced details and a white, UV-resistant waterproof final layer.

Core systemExposed, UV exposed
Applying a white 2K polyurea waterproofing system to a flat roof2K cold appliedFrom prepared surface to white waterproof membrane

PolyShield performs this

Premium 2K polyurea waterproofing

Premium 2K polyurea waterproofing as a complete waterproofing route for larger commercial roofs and concrete roofs and terraces.

  1. Inspect roof structure, moisture and details
  2. Cleaning and repairing weak areas
  3. Apply primer and detail reinforcement
  4. Waterproof membrane delivered in a controlled manner

From damage picture to solution

Problem, cause and effect first visible.

Het probleem

Aged roof layers, open seams or vulnerable details allow water to enter.

Possible causes
  • UV and weather loads
  • Movement of seams and connections
  • Overdue maintenance or previous emergency repairs
Gevolg bij uitstel

Moisture can damage insulation, interior, installations and business processes.

Onze aanpak

Een renovatie afgestemd op het gebouw van ondergrond, details, primer en doorlopend membraan.

De precieze oorzaak stellen we per project vast. Deze uitleg is geen diagnose op afstand.

Business benefits

The value is not just in the new layer.

Lifespan

Maintain a technically suitable roof structure and postpone replacement.

Continuity

Organize renovation per work area around the use of the building.

Risk management

Include critical details before consequential damage occurs.

Maintenance

Een inspecteerbare en lokaal herstelbare aanpak creëren.

RISK OF DELAY

Delay can allow local defects to progress to wet insulation, larger repair zones and damage under the roof.

First have the size, cause, accessibility and desired planning assessed. We then compare repair, renovation and, where necessary, replacement without selling a standard solution in advance.

Have project assessed

Door ons uitgevoerd

Drie toepassingen van een complete vloeibare waterdichting

Bekijk de beginsituatie, voorbereiding en het resultaat. We noemen alleen gegevens die van het project bekend zijn.

Planmatige dakrenovatie schoolgebouw in GoudaGoudaPlanned roof renovation of school building

Approximately 700 m² of outdated bituminous roofing with strong crackle formation, systematically renovated with primer, reinforced details and two layers of white 2K polyurea.

Bekijk dit project →
Dakcoating in Den Haag: 125 m² bitumen bedrijfsdak als cool roof in Den HaagTHE HAGUEDakcoating in Den Haag: 125 m² bitumen bedrijfsdak als cool roof

Bij dit dakcoatingproject in Den Haag is een verouderd en lekkagegevoelig bitumen bedrijfsdak van circa 125 m² gereinigd, geprimerd, op kritische overgangen met geotextiel versterkt en in twee lagen wit afgewerkt als cool roof.

Bekijk dit project →
Terrasdak van 60 m² waterdicht in Vinkeveen in VinkeveenVinkeveenTerrasdak van 60 m² waterdicht in Vinkeveen

Onder de verwijderde terrastegels en het zandpakket bleek de bestaande dakbedekking op meerdere plaatsen te lekken. Het circa 60 m² grote vlak boven een onderliggende ruimte is gereinigd, geprimerd, volledig gewapend met geotextiel en afgewerkt met een polyurethaancoating.

Bekijk dit project →
Opbouw van een waterdichtingssysteem voor een plat bedrijfsdak

System construction

A complete structure, no loose coating.

De visual maakt het functionele principe inzichtelijk. Exacte producten, laagdiktes en verbruiken volgen uit ondergrondonderzoek en de projectspecificatie.

  1. 01
    Prepared surface

    Fixed, clean, repaired and technically assessed

  2. 02
    Surface-specific primer

    Adhesion and pore control tailored to the base

  3. 03
    Detail reinforcement

    Focused on seams, bilges, drains and transitions

  4. 04
    Polyurea membrane

    White, UV-resistant and waterproof final layer

System profile

What this direction is rated for.

Applications
  • Larger commercial roofs
  • Concrete roofs and terraces
  • Metal roofs and gutters
  • Waterproofing under tiling
  • Foundations and underground walls
  • Green roofs and planters
Properties
  • Cold applied with roller or airless
  • Seamless, elastic and tear-bridging
  • High mechanical and weather resistance
  • Early rain resistance within the right conditions
  • White and UV resistant
  • Can be armed locally or completely
Surfaces
  • Concrete and cement screeds
  • Bituminous roofing
  • Metal
  • Technically suitable existing membranes

Application boundaries

Where this system fits primarily, conditionally or non-standard.

The classification helps with the initial selection. Substrate, load, detailing and current system documentation remain decisive.

NOT AS A STANDARD ROUTE
  • Wet or unstable surface
  • Unknown layers without test adhesion
  • Structural defect without repair
  • Undocumented product combination

Beoordeling in de praktijk

Wanneer 2k-polyurea waterdichting kansrijk is

Complete cold-applied two-component system for seamless waterproofing of technically suitable commercial roofs and structures. From surface control and primer to reinforced details and a white, UV-resistant waterproof final layer.

Wanneer dit meestal past

Larger commercial roofs

De ondergrond en detaillering moeten deze systeemroute aantoonbaar toelaten.

Concrete roofs and terraces

De ondergrond en detaillering moeten deze systeemroute aantoonbaar toelaten.

Metal roofs and gutters

De ondergrond en detaillering moeten deze systeemroute aantoonbaar toelaten.

Wat we eerst willen weten

  • Roof structure and residual moisture
  • Bonding of existing layers
  • Slope and puddle formation
  • Seams, upstands and penetrations
  • Constructive movement and accessibility

Wanneer we een andere aanpak adviseren

Natte isolatie niet insluiten Losliggende dakbanen eerst herstellen of vervangen Primer in beginsel verplicht Geen productsystemen combineren zonder schriftelijke goedkeuring

01 / Inspect

We want to know this first.

  • Roof structure and residual moisture
  • Bonding of existing layers
  • Slope and puddle formation
  • Seams, upstands and penetrations
  • Constructive movement and accessibility
02 / Limit

When we don't execute immediately.

  • Do not enclose wet insulation
  • First repair or replace loose roofing membranes
  • Primer mandatory in principle
  • Do not combine product systems without written approval
03 / Substantiate

Which must be demonstrable.

  • Link system variant to current ETA/DoP
  • Verbruik en laagopbouw voor het betreffende project vastleggen
  • Fire and use classification only per approved structure
  • Expected technical useful life is not an automatic project guarantee

Technical proof

Performance is system and structure specific.

The statuses below are deliberately reserved. A proof is only shown as proven after the current document, the system variant and the intended use have been checked.

To be verified on a project basis

ETA/EAD

An ETA applies to the described system kit and its intended use. Document number and current system variant are checked before publication.

To be verified on a project basis

CE and declaration of performance

CE and DoP describe declared product performance; they are not a blanket endorsement of every roofing project.

Construction-related

BROOF classification

Only claimable for the exact tested roof structure, substrate, layer thickness and the stated test suffix, for example BROOF(t1).

To be verified on a project basis

Waterproofing

Test performance and application conditions must correspond to the selected membrane variant and project structure.

To be verified on a project basis

Crack bridging and movement

Class, temperature and layer thickness are taken from the current technical documentation.

To be verified on a project basis

VOC and environmental documentation

VOC, EPD and other environmental claims are only published with a current, traceable source.

Van mogelijke oplossing naar aanbieding

Four pieces of information that really determine the quotation.

01Substrate

Material, condition, moisture, adhesion and existing layers.

02Details

Edges, bilges, drains, penetrations, seams and connections.

03Tax

Water, UV, movement, traffic, use and operating conditions.

04Execution

Accessibility, phasing, safety, planning and weather window.

Implemented white 2K polyurea system on a school roof of approximately 700 square meters
PROJECT FILE / SCHOOL ROOF · APPROXIMATELY 700 M²From outdated bitumen to a completely white 2K waterproofing system.View performance →

Our primary technology

Cold processed. Highly protected.

The two-component membrane is processed without a hot spray installation. This enables a controlled application with roller or airless, depending on the project and work plan.

The waterproofing is not a separate end product. Substrate preparation, primer, critical details, mixing ratio, consumption and application conditions together form the system.

Technology
Cold applied elastic 2K polyurea
Finish
White and UV resistant
Use
Roofs and multiple technically approved structures
Evidence
Alleen claims uit actuele voor het betreffende project documentatie

More than roof coating

One 2K technology, several complete waterproofing systems.

The technology can be widely used, but the system structure is never universal. Each application has its own surface preparation, primer, detailing, consumption and evidence.

Fast-track systems thinking

Faster processing without skipping technical steps.

Under appropriate conditions, quick-drying primers, short overcoat windows and an early rain-resistant 2K membrane can practically limit the implementation time. This is especially valuable at operational business locations where downtime, weather risk and phasing weigh heavily.

  • Surface firstMoisture, cohesion, adhesion and contamination determine whether a fast route is responsible.
  • Primer as system layerThe primer is chosen based on the surface and load; not as a generic addition.
  • Details before the planeSeams, bilges, drains and penetrations are worked out in advance and reinforced where necessary.
  • Register conditionsTemperature, relative humidity, mixing, consumption and recoating time remain control points.
“Snel” is altijd per project. Droging, regenbestendigheid en ingebruikname worden pas na productselectie en controle van de uitvoeringscondities bevestigd.

Technical variant matrix

Not every roof requires the same membrane.

Within the same system family, PolyShield selects the variant that suits UV exposure, layer thickness, root pressure, use and implementation window. This choice will only be made after inspection and document control.

01 / Primary route

Premium elastic 2K polyurea

The broad renovation route for larger commercial roofs and structures, with substrate-specific primer, targeted detail reinforcement and a white UV-resistant final layer.

  • Planned roof renovation
  • Concrete, bitumen and metal
  • Armed and unarmed construction
02 / Exposed and walkable

Fully aliphatic 2K variant

For exposed surfaces where very high UV stability, mechanical stress and long-term water stress come together.

  • Walkable roofs
  • High UV load
  • Protective layer over suitable membranes
03 / High build

Thick-layered 2K variant

Can be assessed as a controlled single-layer variant on a sufficiently smooth and level surface. Details, consumption and surface preparation remain separate system steps.

  • Flat mineral roofs
  • High mechanical resistance
  • Early rainproof route
04 / Root loaded

Root-resistant 2K variant

For green roofs and large planters where demonstrable resistance to root penetration is part of the complete hidden roof structure.

  • Green roofs
  • Planters
  • Protective and drainage layers required
View green roof system →
05 / Alternative fast-track route

Fast drying 1K-PU

A water-based one-component system for suitable roof renovations with short overlay windows and limited weather risk. This is a different technology than our premium 2K polyurea system.

  • Fast maintenance projects
  • Early rain resistance possible
  • Low VOC route according to product specification
Important

“One coat”, “same day ready” and solid rain resistance are never universal promises. They only apply with the correct substrate, layer thickness, temperature, humidity and completely approved structure.

The premium difference

A membrane is only as reliable as the complete system.

A simple coating may be suitable as a maintenance layer. In a waterproof renovation system, the substrate, adhesion and the weakest details are also demonstrably taken into account.

Loose maintenance layer
  • Focus on the visible roof surface
  • Preparation may vary per provider
  • Primer not always part of the approach
  • Mainly aimed at maintenance or reflection
PolyShield 2K system
  • Inspection of roof structure and residual moisture
  • Restoration and cleaning before application
  • Surface-specific primer as a system layer
  • Reinforcement of seams, bilges and penetrations
  • 2K waterproof membrane with controlled consumption
  • Registration and delivery control

Complete system construction

Seven checkpoints before delivery.

  1. 01
    Roof inspection

    Assess roof structure, moisture, adhesion, slope and details.

  2. 02
    Cleaning

    Remove dirt, loose parts and disturbing contaminants.

  3. 03
    Restore

    Treat weak areas and defects before containment.

  4. 04
    Enhance details

    Treat seams, curbs, drains and transitions in a targeted manner.

  5. 05
    Apply primer

    De hechtlaag per project op de ondergrond afstemmen.

  6. 06
    2K membrane

    Check components, mixing, consumption and conditions.

  7. 07
    Deliver

    Record end result, details and relevant implementation data.

Business decision value

Not just waterproof. Also manageable.

For an owner or manager, it is not only the layer applied that counts, but also the predictability of preparation, implementation and maintenance.

01

Fewer interfaces

Substrate, details, primer and membrane are assessed as one project scope.

02

Plannable implementation

Work zones, weather conditions, accessibility and business operations are coordinated in advance.

03

Controllable quality

Consumption, application conditions, details and residual points are included in the delivery.

04

Maintainable solution

Inspection and local repair can become part of the maintenance strategy.

From claim to evidence

Technical performance is part of the tested structure.

01

System variant

Substrate, primer, any reinforcement, membrane consumption and end application are recorded as one variant.

02

Project conditions

Moisture, temperature, details, water load and future use load are assessed before implementation.

03

Classifications

ETA, CE, fire, root and use classifications are only linked to the configuration for which they demonstrably apply.

04

Delivery file

Relevante controles, foto’s, verbruik, afwijkingen en onderhoudspunten worden per project vastgelegd.

First suitability check

Is 2K polyurea suitable for this roof?

This classification is a preselection. A final decision requires inspection, substrate data and, where necessary, measurements or test adhesion.

01 / Promising

Technically suitable for further investigation

  • Stable and sufficiently dry roof structure
  • Repairable seams, edges and details
  • Larger planned renovation project
  • Need a seamless white waterproofing
02 / Investigate first

Additional project information needed

  • Unknown roof structure or old coating
  • Puddle formation, blistering or local detachment
  • PVC/TPO or multiple existing layers
  • Doubts about moisture, adhesion or movement
03 / Restore first

Do not enclose directly with a membrane

  • Wet or saturated insulation
  • Loose roofing
  • Construction defects
  • Unresolved active leak cause

Get a targeted quote faster

Prepare these six pieces of information in advance.

  1. 01Projectadres in Nederland
  2. 02Indicative roof area
  3. 03Type of existing roof covering
  4. 04Photos of roof surface and critical details
  5. 05Known leaks or previous repairs
  6. 06Desired planning and accessibility
Vraag offerte of informatie aan Doe eventueel de DakcheckMeet eventueel uw dak

First calculate your roof area

From address to a usable first project size.

Find the project address on the map, draw one or more roof surfaces and use the calculated surface immediately when screening or requesting a quote.

  1. 01Enter the project address
  2. 02Draw the roof contours
  3. 03Get the estimated area
Vraag offerte of informatie aan Meet eventueel uw dak
The online measurement is indicative. Final quantities follow from inspection and project recording.

Choose by project question

Not a general coating story, but a route that suits your building.

Elke route behandelt een andere zakelijke zoekvraag: van behoud van bestaand bitumen tot schooldaken, productieomgevingen en complexe details. De technische geschiktheid blijft altijd per project.

For larger renovation projects

Have your roof assessed for a complete 2K system quote.

The quotation is tailored to the surface, preparation, details, accessibility, surface and desired planning.

Vraag offerte of informatie aan Discuss via WhatsApp

Frequently asked questions

Technical clarity before application.

Is this system directly suitable for every surface mentioned?

No. The substrate must fall within the approved system scope and is checked for cohesion, moisture, contamination, movement and adhesion. The correct preparation and primer are then recorded.

Is the layer structure shown always the same?

The functions remain recognizable, but primer, reinforcement, number of layers and consumption may differ per substrate and load. The final structure is stated in the project specification.

Can the system be installed over existing waterproofing?

Only when material, mounting and condition are known and a compatible structure can be demonstrated. For unknown membranes or coatings, we first carry out identification and test adhesion.

Is cold-applied 2K polyurea quickly rainproof?

Binnen passende systeem- en uitvoeringscondities zijn vroeg regenbestendige routes mogelijk. Het exacte tijdstip hangt af van het gekozen product, temperatuur, luchtvochtigheid, ondergrond en laagopbouw en wordt daarom voor het betreffende project bevestigd.

Where can 2K polyurea be applied?

Possible applications include commercial roofs, concrete, metal, balconies, terraces, waterproofing under tiling, foundations and certain covered or water-loaded structures. Each application requires its own approved system structure.

What lifespan or warranty applies?

Technical ratings and expected useful lives are for specifically rated systems. The project guarantee also depends on the surface, scope, implementation, maintenance and written agreements.

What is the first step?

A project screening and inspection. We record construction, surface, damage picture, water load, details, accessibility and desired planning.

Past deze mogelijke oplossing bij uw constructie?

Vraag offerte of informatie aan Doe eventueel de technische check
2K polyurea for larger projectsVraag direct aan; meten kan eventueel later.
Meet eventueel uw dakOfferte of informatie