POLYSHIELDSYSTEMSRequest a quotation

Roofs

Waterproofing system for concrete roofs

Elastic waterproofing for mineral roof substrates, with repair of pores, cracks and transitions before membrane application.

Core systemExposed
Deze pagina beschrijft de techniek. Concrete dakuitvoering en aanvragen staan op PolyShield Dakcoatings.
Doorsnede van een volvlaks gewapend polyureamembraan op een cementgebonden ondergrond

PolyShield performs this

Waterproofing system for concrete roofs

Waterproofing system for concrete roofs as a complete waterproofing route for concrete roof slabs and technical roofs.

  1. Inspect roof structure, moisture and details
  2. Cleaning and repairing weak areas
  3. Apply primer and detail reinforcement
  4. Waterproof membrane delivered in a controlled manner

From damage picture to solution

Problem, cause and effect first visible.

Het probleem

Aged roof layers, open seams or vulnerable details allow water to enter.

Possible causes
  • UV and weather loads
  • Movement of seams and connections
  • Overdue maintenance or previous emergency repairs
Gevolg bij uitstel

Moisture can damage insulation, interior, installations and business processes.

Onze aanpak

Een renovatie afgestemd op het gebouw van ondergrond, details, primer en doorlopend membraan.

De precieze oorzaak stellen we per project vast. Deze uitleg is geen diagnose op afstand.

Business benefits

The value is not just in the new layer.

Lifespan

Maintain a technically suitable roof structure and postpone replacement.

Continuity

Organize renovation per work area around the use of the building.

Risk management

Include critical details before consequential damage occurs.

Maintenance

Een inspecteerbare en lokaal herstelbare aanpak creëren.

RISK OF DELAY

Delay can allow local defects to progress to wet insulation, larger repair zones and damage under the roof.

First have the size, cause, accessibility and desired planning assessed. We then compare repair, renovation and, where necessary, replacement without selling a standard solution in advance.

Have project assessed →

System profile

What this direction is rated for.

Applications
  • Concrete roof slabs
  • Technical roofs
  • Cement-bound slope layers
  • Walkable inspection areas
Properties
  • Crack bridging system
  • High adhesion
  • UV-resistant variant
  • Resistant to high water loads
Surfaces
  • Concrete
  • Cement screed
Doorsnede van een volvlaks gewapend polyureamembraan op een cementgebonden ondergrond

System construction

Volvlaks gewapend polyureamembraan

De visual maakt het functionele principe inzichtelijk. Exacte producten, laagdiktes en verbruiken volgen uit ondergrondonderzoek en de projectspecificatie.

Voorbeeld op beton of cementdekvloer. De gekozen systeemopbouw bepaalt de primer, wapening en laagdikte.

  1. 01
    Voorbereide cementgebonden ondergrond

    Vaste en gereinigde basis voor de nieuwe lagen.

  2. 02
    Passende hechtprimer

    Verbindt de ondergrond met het membraan.

  3. 03
    Polyurea basislaag met volvlakse wapening

    De wapening wordt over het hele vlak in de basislaag opgenomen.

  4. 04
    Afdekkende polyurealaag

    Sluit de wapening in en maakt het waterdichte membraan af.

Application boundaries

Where this system fits primarily, conditionally or non-standard.

The classification helps with the initial selection. Substrate, load, detailing and current system documentation remain decisive.

NOT AS A STANDARD ROUTE
  • Wet or unstable surface
  • Unknown layers without test adhesion
  • Structural defect without repair
  • Undocumented product combination

Beoordeling in de praktijk

Wanneer betonnen daken kansrijk is

Elastic waterproofing for mineral roof substrates, with repair of pores, cracks and transitions before membrane application.

Wanneer dit meestal past

Concrete roof slabs

De ondergrond en detaillering moeten deze systeemroute aantoonbaar toelaten.

Technical roofs

De ondergrond en detaillering moeten deze systeemroute aantoonbaar toelaten.

Cement-bound slope layers

De ondergrond en detaillering moeten deze systeemroute aantoonbaar toelaten.

Wat we eerst willen weten

  • Tensile strength
  • Residual moisture
  • Cracks and joints
  • Pores and gravel nests
  • Slope

Wanneer we een andere aanpak adviseren

Constructieve scheuren laten beoordelen Onvoldoende sterk beton eerst herstellen Negatieve waterdruk apart behandelen

01 / Inspect

We want to know this first.

  • Tensile strength
  • Residual moisture
  • Cracks and joints
  • Pores and gravel nests
  • Slope
02 / Limit

When we don't execute immediately.

  • Have structural cracks assessed
  • Repair insufficiently strong concrete first
  • Treat negative water pressure separately
03 / Substantiate

Which must be demonstrable.

  • Measurably record substrate strength and moisture
  • Scheurdetails per project tekenen
  • Classification by system variant

Technical proof

Performance is system and structure specific.

The statuses below are deliberately reserved. A proof is only shown as proven after the current document, the system variant and the intended use have been checked.

Aangetoond

ETA/EAD

ETA 24/1247 is gecontroleerd tegen EAD 030350-00-0402. De beoordeling geldt voor de beschreven systeemkit en het bedoelde gebruik.

ETA 24/1247 · EAD 030350-00-0402
Aangetoond

CE and declaration of performance

DoP 4951-08 beschrijft de gedeclareerde prestaties en componenten; dit is geen algemene goedkeuring van ieder dakproject.

DoP 4951-08
Construction-related

BROOF classification

Alleen claimbaar binnen de geteste opbouw, ondergrond, laagdikte, dakhelling en het vermelde testsuffix BROOF(t1).

ETA 24/1247 · helling ≤ 20° op niet-brandbare ondergrond
To be verified on a project basis

Waterproofing

Test performance and application conditions must correspond to the selected membrane variant and project structure.

To be verified on a project basis

Crack bridging and movement

Class, temperature and layer thickness are taken from the current technical documentation.

To be verified on a project basis

VOC and environmental documentation

VOC, EPD and other environmental claims are only published with a current, traceable source.

Van mogelijke oplossing naar aanbieding

Four pieces of information that really determine the quotation.

01Substrate

Material, condition, moisture, adhesion and existing layers.

02Details

Edges, bilges, drains, penetrations, seams and connections.

03Tax

Water, UV, movement, traffic, use and operating conditions.

04Execution

Accessibility, phasing, safety, planning and weather window.

Frequently asked questions

Technical clarity before application.

Is this system directly suitable for every surface mentioned?

No. The substrate must fall within the approved system scope and is checked for cohesion, moisture, contamination, movement and adhesion. The correct preparation and primer are then recorded.

Is the layer structure shown always the same?

The functions remain recognizable, but primer, reinforcement, number of layers and consumption may differ per substrate and load. The final structure is stated in the project specification.

Can the system be installed over existing waterproofing?

Only when material, mounting and condition are known and a compatible structure can be demonstrated. For unknown membranes or coatings, we first carry out identification and test adhesion.

What lifespan or warranty applies?

Technical ratings and expected useful lives are for specifically rated systems. The project guarantee also depends on the surface, scope, implementation, maintenance and written agreements.

What is the first step?

A project screening and inspection. We record construction, surface, damage picture, water load, details, accessibility and desired planning.

Van technische systeemkeuze naar een concreet dakproject.

Bekijk uitvoering en offerte ↗Doe eventueel de technische check